You are here:
AXTER ROOF WATERPROOFING AND INSULATION SPECIFICATION |
| Supporting deck |
Existing waterproofing |
| Application |
Single ply waterproofing with insulation |
| Roof type |
Warm |
| System reference |
ECOLINE ADH |
|
Existing waterproofing – Single layer waterproofing system with thermal insulation
Single ply PVC-p membranes should only be applied over a continuous substrate which provides full support. Substrate materials used to form the roof deck in flat roofs should be those listed in BS 6229:2003 Flat roofs with continuously supported coverings – Code of practice.
The waterproofing system should conform to the requirements of British Standard BS EN 13956: Flexible sheets for waterproofing – Plastic and rubber sheets for roof waterproofing – Definitions and characteristics.
Axter’s ECOLINE range of PVC-p single ply membranes has been awarded BBA Agrément Certificate number 12/4947. |
| Supporting deck |
Existing membrane or asphalt waterproofing system |
| Deck preparation |
Ensure substrate is sound, cut and seal all blisters, remove details. Prime all surfaces with a suitable bituminous primer and allow to dry in accordance with Annex C of British Standard BS 6229:2003. |
| Vapour control layer |
Existing waterproofing will act as the vapour control layer. |
| Thermal insulation |
Coated glass tissue faced PIR insulation, thickness to meet required U-value laid in HYRA-STIK PU adhesive. |
| Waterproofing system |
ECOLINE ADH 1.2 mm fully bonded in ADH ADHESIVE (solvent free). |
| Principal details |
ECOLINE FM 1.2 using FM/D CONTACT ADHESIVE. |
| Pipe penetrations |
ECO/D. |
| Finishes |
Self protected system. |
|
Product substitution
- ECOLINE ADH 1.2 and ECOLINE FM 1.2 can be replaced with 1.5 versions for 20 year warranty.
NBS specification
Please view the Axter NBS specification for further information.